Air cooled:
PAP05A1; PAP05A1-F; PAP10A1; PAP10A1-F; PAP20A; PAP20A-F.
Water cooled
PAP05A1-W; PAP05A1-FW; PAP10A1-W; PAP10A1-FW; PAP20B1-W; PAP20B1-FW; PAP40B-W; PAP40B-FW.
※ 1 The temperature control range noted does not necessarily indicate the actual controllable range possible. The range of temperature control depends on the condition of the air supplied at the intake.
※ 2 When the air temperature and humidity is stable at the air intake. Noted accuracy is based on measurement by the internal controller at a single air outlet point.
※ 3 The noted external static pressure is when the controlled air is regulated at the outlet to produce the maximum rated processing air flw.
※ 4 Height includes outlet port.
※ 5 The HEPA fiter box is shipped in a separate package from the main unit and must be installed on-site.
※ 6 Source voltage phase unbalance should be less than ± 3%.
※ 7 Maximum value within the range of unit specifiations.
※ 8 The fiure noted is when the equipment is operating at the highest capacity of its normal operating range.
※ 9 Noise level can be decreased by installing a noise-reducing intake duct.
Specification – Thông số kỹ thuật
※ 1 The temperature control range noted does not necessarily indicate the actual controllable range possible. The range of temperature control depends on the condition of the air supplied at the intake.
※ 2 Values indicated are for when the intake air temperature and humidity, and supply water temperature and supply water flow rate are stable. Noted accuracy is based on measurement by the internal controller at a single air outlet point.
※ 3 The noted external static pressure is when the controlled air is regulated at the outlet to produce the maximum rated air flow.
※ 4 Height includes outlet port.
※ 5 The HEPA filter box is shipped in a separate package from the main unit and must be installed on-site.
※6 When processing at the maximum air flow and at the highest cooling capacity, the difference between the cooling water inlet and outlet ports is 6.5℃ .
※ 7 Source voltage phase unbalance should be less than ± 3%.
※ 8 Maximum value within the range of unit specifications.
※ 9 The figure noted is when the equipment is operating at the highest capacity of its normal operating range.
※ 10 The noise level may be lowered by installing noise-absorbing ducting.
NGUYEN THANH THAI (Mr.) – Division Manager
Chiller – Dehumidifier and PAP Division
Hand phone: (+84)-0938.177.737
Email: thanhthai@yori.com.vn
Skype: thaint0912
FOR EVERYTHING YOU VALUE
————————————————————————————————————
YORI EQUIPMENT CO., LTD
Website: Máy làm lạnh nước biến tần ORION – Inverter Chiller ORION
Máy hút ẩm ORION – Dehumidifier ORION.
————————————————————————————————————
Số 3, Đường số 9, Khu Phố 2, Phường Bình Chiểu, TP Thủ Đức, TP Hồ Chí Minh.
028 36206196 028 36203196
0938.177.737
thanhthai@yori.com.vn
thaint0912
Dear The Value Customer, Kính gởi Quý Khách Hàng, We – Yori Equipment Co.,Ltd are very grateful to you for your support when...
RKE1500B1-V-G2 ORION High- Spec Model Model: RKE1500B1-V-G2Cooling capacity: 5.3KW Delivery to The Customer - Vận chuyển máy làm lạnh nước...
Dear The Value Customer, Kính gởi Quý Khách Hàng, We – Yori Equipment Co.,Ltd are very grateful to you for your support when...
Dear The Value Customer, Kính gởi Quý Khách Hàng, We – Yori Equipment Co.,Ltd are very grateful to you for your support when...
Dear The Value Customer, Kính gởi Quý Khách Hàng, We – Yori Equipment Co.,Ltd are very grateful to you for your support when...